Description
Allen-Bradley 1756-BA1 Lithium PLC Backup Battery
The Allen-Bradley 1756-BA1 battery is a non-rechargeable lithium backup battery for compatible ControlLogix industrial automation controllers.
Manufactured under the Allen-Bradley brand by Rockwell Automation, this battery is specified for selected Series A ControlLogix systems.
The 1756-BA1 supports the controller’s battery-backed memory functions. Additionally, the manufacturer identifies it as a replacement battery assembly for compatible ControlLogix 5560 applications.
Key Features
- 1756-BA1 Part Number: Exact battery reference for supported controllers.
- Primary Lithium Battery: Non-rechargeable industrial backup technology.
- Series A Compatibility: Designed for compatible ControlLogix 1756-L6x Series A controllers.
- Memory Backup Application: Supports designated battery-backed controller memory.
- Industrial Battery Assembly: Uses the connection arrangement specified for supported controllers.
- Pack of 1: Includes one lithium backup battery assembly.
Allen-Bradley 1756-BA1 Battery Specifications
| Specification | Details |
|---|---|
| Brand | Allen-Bradley |
| Manufacturer | Rockwell Automation |
| Model | 1756-BA1 |
| Series | A |
| Battery Type | Primary Lithium |
| Rechargeable | No |
| Compatible Controller Family | ControlLogix |
| Compatible Series | Selected Series A Controllers |
| Application | PLC Memory Backup |
| Pack Quantity | 1 |
| Package Origin Marking | Made in Japan |
Compatible Allen-Bradley PLC Controllers
Rockwell Automation identifies the 1756-BA1 battery for selected ControlLogix Series A controllers.
These include:
- 1756-L61 Series A
- 1756-L62 Series A
- 1756-L63 Series A
The manufacturer also lists 1756-BA1 for certain older ControlLogix controller references. However, compatibility depends on the exact controller catalogue number and series.
Therefore, confirm the complete controller model before purchasing.
Why Do ControlLogix Controllers Need Backup Batteries?
Certain ControlLogix controllers use lithium backup batteries to retain designated memory contents when the normal power supply is unavailable.
For example, a supported controller may rely on the battery to preserve battery-backed information during a power interruption.
Furthermore, appropriate battery maintenance helps reduce the risk of unexpected memory loss.
Nevertheless, exact retention behaviour depends on the controller model, memory configuration and battery condition.
Allen-Bradley 1756-BA1 vs 1756-BA2
Although both batteries are associated with ControlLogix controllers, they are not interchangeable by default.
1756-BA1
- For specified Series A ControlLogix controllers
- Primary lithium battery
- Manufacturer part number: 1756-BA1
1756-BA2
- For specified Series B ControlLogix controllers
- Different battery assembly reference
- Manufacturer part number: 1756-BA2
Consequently, always verify the controller series before selecting a replacement.
Using an incorrect battery may cause equipment problems or damage.
Installation and Replacement Guidance
Before replacing the battery, identify the exact ControlLogix controller and consult Rockwell Automation’s installation instructions.
- Verify the controller catalogue number and series.
- Confirm that 1756-BA1 is the specified battery.
- Follow the required precautions to protect controller memory.
- Inspect the replacement battery and its connection.
- Install the battery according to the applicable Rockwell Automation procedure.
- Record the installation date if required by the maintenance instructions.
- Check the controller’s battery-status indicator.
Important: Battery replacement should be performed by qualified industrial maintenance personnel. Incorrect procedures can result in memory loss or equipment downtime.
Battery Storage and Handling
Store unused batteries in a cool, dry environment.
Moreover, keep the battery protected from excessive heat and conductive materials.
Before installation, inspect the battery’s condition and confirm its storage history.
Important Battery Safety Instructions
- Do not recharge the battery.
- Do not short-circuit its terminals.
- Avoid crushing, puncturing or dismantling the cell.
- Keep away from excessive heat and fire.
- Do not reverse battery connections.
- Never install a damaged or leaking battery.
- Keep away from children.
- Dispose of spent batteries according to applicable regulations.
Frequently Asked Questions
What is the Allen-Bradley 1756-BA1 battery used for?
It is a lithium memory-backup battery for compatible ControlLogix controllers.
Which ControlLogix controllers support this battery?
Rockwell Automation specifies 1756-BA1 for selected Series A controllers, including compatible 1756-L61/A, 1756-L62/A and 1756-L63/A units.
Is 1756-BA1 interchangeable with 1756-BA2?
No. The two battery references are intended for different controller series.
Is the 1756-BA1 rechargeable?
No. It is a non-rechargeable primary lithium battery.
Does this product include one battery?
Yes. Each sales unit contains one battery assembly.
Can it be used with every Logix 5000 controller?
No. Logix 5000 includes multiple controller families and generations. Confirm the exact battery part number specified for your model.
How should the battery be installed?
Follow the official Rockwell Automation installation instructions for the specific controller model and series.
Buy Allen-Bradley 1756-BA1 Backup Battery Online at ArcEin
Order the Allen-Bradley 1756-BA1 Series A Lithium PLC Backup Battery from ArcEin for compatible ControlLogix industrial automation applications.
For bulk orders or assistance identifying the correct battery reference, contact contactus@arcein.in.






Reviews
There are no reviews yet.